Resource center

Welcome to our Resource Center. From this page, you can access all our documentation.

31/03/2019

MAGNUM™ 5900 series Specifications

Applications Mass spectrometer replacements High pressure High dynamic range Compact, plug-in applications

Specifications
174.38 KB pdf

31/03/2019

Ion Beam Profiler Specification

Featuring: Low Light CMOS High-Speed Camera Large, Customizable Microchannel Plate Simple Acquisition of Analog or Digital Images Immediate Feedback of Ion Loss and Optimization

Specifications
367.64 KB pdf

31/03/2019

High Voltage Power Supply PF1055

Quad output, High Voltage Rack Mount Power Supply designed for use with PHOTONIS bipolar time-of-flight detectors

Specifications
110.89 KB pdf

31/03/2019

Glass Capillary Arrays Specification Photonis manufactures our Glass Capillary Arrays to consist of millions of precision glass tubes fused together to produce a uniform and mechanically rigid device in square, rectangular and round shapes. With their strong, self‐ supporting structure, Glass Capillary Arrays have excellent thermal and chemical stability and sieve‐like filtration abilities to be used in a wide variety of applicati...
Specifications
158.88 KB pdf

31/03/2019

Resistive Glass Drift Tubes with Air Stable Surface and Multiple Voltage Statges Resistive Glass provides key benefits for ion mobility drift tubes, such as highly uniform electric fields with minimal radial inhomogeneities, simple one-piece construction and containment for counter-flow gas. The combination of uniform electric field and the turbulence-free counter-flow gas produces resolving powers of over 100. However, for some applications, the resistivity drift of Resist...
Poster
859.97 KB pdf

31/03/2019

Isolating the Effects of Microchannel Plate Parameters on the Ultimate Resolution in Time-of-Flight Detectors

This paper examines the effects of pore sizes and bias angles of the Microchannel Plates used in Time of Flight Detectors. Experiments were done to determine how the parameters of the MCP could be manipulated to minimize time jitter to ultimately improve the detection resolution of a Time of Flight detector. Efforts to control flatness of the MCP are also discussed.

Poster
1.13 MB pdf

31/03/2019

Capillary Inlet Tubes for Enhanced Ion Transport

Development of Resistive Glass Multi-Capillary Inlet Tubes for Enhanced Ion Transport

Resistive Glass has proven to be successful at increasing the ion transmission in atmospheric pressure ionization sources. This paper discusses the manufacture of a multi-channel inlet tube and its effects on ion throughput.

Poster
5.61 MB pdf

31/03/2019

ALD MCP Poster

Using Atomic Layer Deposition (ALD) to Enhance Microchannel Plates (MCPs) for Mass Spectrometry Matthew Breuer; Paula Holmes, Ph.D.; John Harper Photonis Scientifi c, Inc., Sturbridge, MA

Poster
655.77 KB pdf